You are here
CMOS-MEA5000+MEA2100-256-System
Bundle of CMOS-MEA5000 and MEA2100-256-System.
CMOS-MEA workstation for recording and analyzing data from active CMOS-MEAs. With integrated data acquisition for recording from 4225 MEA electrodes and 8 additional analog channels. Integrated filter amplifier and 3-channel voltage stimulus generator for stimulating 1024 stimulation sites on the CMOS chip.
MEA2100 workstation for recording and analyzing data from 256-electrode MEAs (microelectrode array). With integrated data acquisition for recording from 256 MEA electrodes and 8 additional analog channels. Integrated filter amplifier and 3-channel current or voltage stimulus generator.
Complete with interface board, CMOS-MEA-headstage, MEA2100-256 headstage, data acquisition computer with preinstalled software, perfusion kit, and accessories. USB High Speed data transfer with a sampling rate of up to 50 kHz/channel (25 kHz/channel for CMOS).
Â
• CMOS-MEA5000 headstage:
 Pre- and filter amplifier with integrated data acquisition,
 stimulus generator, and analog-digital converter
 - Bandwidth adjustable via software
 - Data resolution: 14 bit
 - Direct access to each stimulation site for stimulation
   via internal stimulus generator.
 - Control of stimulator via the included data acquisition
   software CMOS-MEA-Control
 - Integrated blanking circuit for stimulus artifact suppression
 - 3 independent stimulus generators
 - Voltage stimulation at max. +/-2 V
 - Sampling rate max. 25 kHz per channel
• MEA2100 headstage (MEA2100-HS256):
 Pre- and filter amplifier with integrated data acquisition and
 analog-digital converter
 - Bandwidth adjustable via software
 - Data resolution: 24 bit
 - Direct access to each electrode for stimulation via internal stimulus generator
 - Control of stimulator via the included data acquisition software
 - Integrated blanking circuit for stimulus artifact suppression
 - 2 independent stimulus generators
 - Current stimulation at max. +/-1.5 mA
 - Voltage stimulation at max. +/-10 V
 - Sampling rate max. 50 kHz per channel
 - Integrated heating element (PT 100 sensor)
 - With installed metal plate for fixing of perfusion equipment
• Interface board multiboot (IFB-C):
 Interface board with signal processor for real-time signal
 detection and feedback
 Includes various in-/outputs:
 - 16 possible boot images to operate all MCS headstages
of the modular 2100 amplifier suite
 - 16-bit digital input/output channels for TTL integration, 3.3/5 V compatible
(All channels accessible on the backside via Honda-PCS-XE68LFD,
additional bit 0-3 digital in and bit 0-3 digital out accessible on
the front via LEMO EPL.00.250.NTN)
 - Channel definition via software: IFB-Control
(free to download) – Boot image definition
 - 8 analog input channels, +/- 10 V voltage input range
@ 24 bit ADC accessible on the front
(All channels via DIL10Header-100mil, channel 1 and 2
additional via LEMO EPL.00.250.NTN)
 - Audio/stereo out (standard stereo jack 3.5 mm)
 - USB-3.0 type C data transfer to PC (cable included)
 - iX industrial, type B cable for connecting IFB-C to
headstage/signal collector unit/receiver (cable included)
 - DSP-JTAG for direct programming of the built-in DSP
(DIL14Header-100mil-angeled)
 - Physical ground socket (4 mm socket)
 - External power supply included: 24 V/65 W, 110-240 V
• CMOS-MEA-Control program and Multi Channel Suite programs:
 - Data acquisition and analysis softwares
 - Including a 2 years maintenance package (software updates
   and support)
• Data acquisition computer:
 - PC with 2 monitors, keyboard and mouse
 - With preinstalled hardware operating system and software
Perfusion kit:
• TC02:
 2-channel temperature controller for biological samples
 - Set-point temperature reached fast within 30 seconds to 5 minutes
 - Control temperature range from ambient temperature to +50 °C
 - Precision controller using PI characteristics
 - 100-240 V input voltage range, external power supply
• TCX_Control Program:
 TCX-Control is a software to control the MCS temperature controllers. Through
 the quick USB interface, it is possible to adjust all settings of the TC01/02
 temperature controller online.
• 1 x PH01:
 - Heatable perfusion cannula with temperature sensor
 - Controlled by TC01/02
• 1 x PPS2:
 - Peristaltic perfusion system with one inlet and one drain pump
 - Controlled by software or touch pad
 - Flow rate: 0 - 30 ml/min
• Perfusion Accessories:
 - 2 magnetic perfusion holders
 - Replacement set of fluidic devices (PPS2-Set-F)
• Accessories:
 - Signal generator
 - Spare parts
 - CMOS dark chamber
 - CMOS tissue holder
 - USB memory stick with user manuals and software
Technical specifications as specified in the data sheet unless noted otherwise in the order.