MEA2100-256-System

MEA workstation for recording and analyzing data from 256-electrode MEAs (microelectrode array). With integrated data acquisition for recording from 256 MEA electrodes and 8 additional analog channels. Integrated filter amplifier and 2-channel current or voltage stimulus generator.
Complete with MEA2100-256-headstage, interface board, data acquisition and analysis software, power supply, and accessories. USB High Speed data transfer with a sampling rate of up to 50 kHz/channel.

Data acquisition and analysis software Multi Channel Suite:

- Including a 2 years maintenance package (software updates and support)

MEA2100 headstage (MEA2100-HS256):

Pre- and filter amplifier with integrated data acquisition and analog-digital converter
- Gain and bandwidth adjustable via software
- Data resolution: 24 bit
- Direct access to each electrode for stimulation via internal stimulus generator
- Control of stimulator via the included data acquisition software
- Integrated blanking circuit for stimulus artifact suppression
- 2 independent stimulus generators
- Current stimulation at max. +/-1.5 mA
- Voltage stimulation at max. +/-10 V
- Sampling rate max. 50 kHz per channel
- Integrated heating element (PT 100 sensor)
- With installed metal plate for fixing of perfusion equipment

Interface board multiboot (IFB-C):

Interface board with signal processor for real-time signal detection and feedback
Includes various in-/outputs:
- 16 possible boot images to operate all MCS headstages of the modular 2100 amplifier suite
- 16-bit digital input/output channels for TTL integration, 3.3/5 V compatible (All channels accessible on the backside via Honda-PCS-XE68LFD, additional bit 0-3 digital in and bit 0-3 digital out accessible on the front via LEMO EPL.00.250.NTN)
- Channel definition via software: IFB-Control (free to download) – Boot image definition
- 8 analog input channels, +/- 10 V voltage input range @ 24 bit ADC accessible on the front (All channels via DIL10Header-100mil, channel 1 and 2 additional via LEMO EPL.00.250.NTN)
- Audio/stereo out (standard stereo jack 3.5 mm)
- USB-3.0 type C data transfer to PC (cable included)
- iX industrial, type B cable for connecting IFB-C to headstage/signal collector unit/receiver (cable included)
- DSP-JTAG for direct programming of the built-in DSP (DIL14Header-100mil-angeled)
- Physical ground socket (4 mm socket)
- External power supply included: 24 V/65 W, 110-240 V

Accessories:

- Cable assembly
- Test model probe
- Signal generator
- Spare parts
- CD with user manuals and software

Technical specifications as specified in the data sheet unless noted otherwise in the order.

References

Documents
Software
Accessories

MEA2100-headstage for one 256-electrode MEA.

Headstage to record data from one 256-electrode MEA. Needs to be connected to IFB (needs to be ordered separately).
• MEA2100 headstage (MEA2100-256-HS):
  Pre- and filter amplifier with integrated data acquisition and analog-digital converter
  - Bandwidth adjustable via software Multi Channel Suite
  - Data resolution: 24 bit
  - Direct access to each electrode for stimulation via internal stimulus generator.
  - Control of stimulator via the included data acquisition software
  - Current stimulation at max. +/-1.5 mA

Perfusion kit for MEA-Systems including TC02, PH01, PPS2, and 2 MPH.

Interface board with signal processor for real-time signal detection and feedback. Receives data from MEA2100-Headstages, Multiwell-MEA-Headstage, CMOS-MEA5000-Headstage, ME2100-Systems or W2100-Systems.

Interface board with signal processor for real-time signal detection and feedback. Receives data from MEA2100-Headstages, Multiwell-MEA-Headstage, CMOS-MEA5000-Headstage, ME2100-Systems or W2100-Systems.

Video microscope table with one video microscope underneath. Images the electrode field of a microelectrode array (MEA) in an amplifier placed on top of the table and transfers the image via USB 3.0 to a computer. Suitable for all MEA1060 amplifiers, USB-MEA32-STIM4-System, USB-MEA256-System, MEA2100-HS32, MEA2100-HS60, and MEA2100-HS120.

Optical stimulator for MEA2100-HS60/120/256

LED for optical stimulation for MEA2100-System 
  - Wavelength: 720nm

LED for optical stimulation for MEA2100-System 
  - Wavelength: 655nm

LED for optical stimulation for MEA2100-System 
  - Wavelength: 627nm

LED for optical stimulation for MEA2100-System 
  - Wavelength: 590nm

LED for optical stimulation for MEA2100-System 
  - Wavelength: 567nm

Pages

MEAs

Microelectrode array for USB-MEA256-System and MEA2100-HS256:
TiN electrodes, SiN isolator, contact pads and tracks transparent (ITO), with 4 internal reference electrodes, electrode grid 16x16, 252 recording electrodes, electrode spacing 30µm, electrode diameter 8µm, warranty: 6 months

Please note: Channel maps in the Multi Channel Suite software are dependent on the recording system you are using (USB-MEA256-System or MEA2100-256-System).


Microelectrode array for MEA2100-HS256 and USB-MEA256-System:

TiN electrodes, SiN isolator, contact pads and tracks transparent (ITO), with internal reference electrode, electrode grid 16x16, 256 electrodes, electrode spacing 60µm, electrode diameter 10µm, warranty: 6 months.

Please note: Channel maps in the Multi Channel Suite software are dependent on the recording system you are using (USB-MEA256-System or MEA2100-256-System).


Microelectrode array for USB-MEA256-System and MEA2100-HS256:

TiN electrodes, SiN isolator, contact pads and tracks transparent (ITO), with internal reference electrode, electrode grid 16x16, 256 electrodes, electrode spacing 100µm, electrode diameter 30µm, warranty: 6 months.

Please note: Channel maps in the Multi Channel Suite software are dependent on the recording system you are using (USB-MEA256-System or MEA2100-256-System).


Microelectrode array for USB-MEA256-System and MEA2100-HS256:

TiN electrodes, SiN isolator, contact pads and tracks transparent (ITO), with internal reference electrode, electrode grid 16x16, 256 electrodes, electrode spacing 200µm, electrode diameter 30µm, warranty: 6 months.

Please note: Channel maps in the Multi Channel Suite software are dependent on the recording system you are using (USB-MEA256-System or MEA2100-256-System).


Microelectrode array with 256 electrodes on thin recording field for USB-MEA256-System and MEA2100-HS256:
180 µm thin recording area, TiN electrodes, SiN isolator, ITO conductive strips, with 4 internal reference electrodes, electrode grid 16x16, 252 recording electrodes, electrode spacing 200 µm, electrode diameter 30 µm, without ring, warranty: 6 months

Please note: Channel maps in the Multi Channel Suite software are dependent on the recording system you are using (USB-MEA256-System or MEA2100-256-System).


256-6wellMEA-iR-ITO-rcr

6-well microelectrode array for USB-MEA256-System and MEA2100-HS256:

TiN electrodes, SiN isolator, contact pads and tracks transparent (ITO), with 6 internal reference electrodes, electrode grid 7x6 in each well, 252 recording electrodes and 6 internal reference electrodes, 6-well layout, 42 recording electrodes per well, electrode spacing 200µm, electrode diameter 30µm, warranty: 6 months.

Please note: Channel maps in the Multi Channel Suite software are dependent on the recording system you are using (USB-MEA256-System or MEA2100-256-System).


9-well microelectrode array for USB-MEA256-System and MEA2100-HS256:

TiN electrodes, SiN isolator, contact pads and tracks transparent (ITO), with internal reference electrodes, electrode grid 6x5 recording + 2 stimulation electrodes in each well, 252 electrodes plus 9 internal reference electrodes, 9 well layout, 26 recording electrodes per well, electrode spacing 300µm, electrode diameter 30µm, warranty: 6 months.

Please note: Channel maps in the Multi Channel Suite software are dependent on the recording system you are using (USB-MEA256-System or MEA2100-256-System).