MEA2100-Lite-System

Manufacturer: 
Multi Channel Systems MCS GmbH
Quality Made in Germany
MEA workstation for recording and analyzing data from 60-electrode MEAs (microelectrode array). With integrated data acquisition for recording from 60 MEA electrodes and 8 additional analog channels. Integrated filter amplifier and 3-channel current or voltage stimulus generator. 
Complete with MEA2100-60-headstage, MCS-Lite interface board, CD with software, and accessories. USB High Speed data transfer with a sampling rate of up to 32 kHz/channel.
 
  • MEA2100 headstage (MEA2100-HS60):
    Pre- and filter amplifier with integrated data acquisition and analog-digital converter
    - Bandwidth adjustable via software
    - Data resolution: Up to 24 bit
    - Direct access to each electrode for stimulation via internal stimulus generator
    - Control of stimulator via the included data acquisition software
    - Integrated blanking circuit for stimulus artifact suppression
    - 3 independent stimulus generators
    - Current stimulation at max. +/-1 mA
    - Voltage stimulation at max. +/-10 V
    - Sampling rate with MC_Rack software: max. 32 kHz per channel, with Multi Channel Suite software: max. 25 kHz per channel
    - Integrated heating element (PT 100 sensor)
    - With installed metal plate for fixing perfusion equipment 

  • MCS-Lite interface board 3.0 (MCS-Lite-IFB):
    Includes various in-/outputs:
    - 4x Digital Out: Interface for output bit 0 - 3 of the 16-bit digital input / output channels (Lemo connector)
    - 4x Digital In for synchronization with other instruments (bit 0 - 3)(Lemo connector)
    - Digital IN / OUT: Interface for 16-bit digital input / output channels. Generates or accepts TTL-pulses.
    - 1x Stereo Out: Possibility to export 2 channels (e.g on an oscilloscope or headphones making the signals audible)
    - 2x Analog IN: Interface for 2 additional analog inputs (channel 1 and 2) (Lemo connector)
    - Analog IN: 8-channel Analog input (channel 1 - 8)
    - 1x Ground
    - 1x Universal Serial Bus High Speed for transferring digitally converted data to any data acquisition computer with a sampling rate of up to 32 kHz (USB High Speed cable)
    - External power supply: 100-240 V input voltage range

  • Data acquisition and analysis software:
    - Including a 2 years maintenance package (software updates and support)

  • Accessories:
    - Cable assembly
    - Test model probe
    - Signal generator
    - Spare parts
    - CD with user manuals and software

 

Technical specifications as specified in the data sheet unless noted otherwise in the order.

 

References

Documents
Software
Accessories

Metal plate for placing MPH (magnetic perfusion holder) on MEA2100-headstage for one 60-electrode MEA (MEA2100-HS60) or one 120-electrode MEA (MEA2100-HS120).

Perfusion element to use perforated MEAs (pMEA) together with MEA2100-headstage.

Revision A for MEA2100-HS60 or -HS120 with serial number 1-142 or MEA2100-Lite-HS with serial number 90001-90025.

Heating element with Pt100 sensor, spare part for MEA2100-HS(2x)60/-HS120.

  • Bore hole size: 8 mm

Revision A for MEA2100-HS60 or -HS120 with serial number 1-142 or MEA2100-Lite-HS with serial number 90001-90025 and all versions of the MEA2100-HS2x60.

Digital in/out extention.

o-Ring-PGP:
- o-Ring for use with perfusion ground plates for all MEA1060 amplifiers and MEA2100-HS(2x)60/120
- Silicone
- 40x1mm, set of three

Data transfer cable for MEA2100-Systems

  • Connecting MEA2100-headstage and interface board

68-pin MCS standard cable, 0.5m.

68-pin MCS standard cable, 1m.

68-pin MCS standard cable, 3m.

Cable with Lemo connectors on both ends.